Flow rate (litre/min)
Drive speed (rpm)
Limited to 2 bar below 50 rpm Flow rate varies with tube material, discharge pressure, suction and viscosity
620RE4 performance graph
Flow rate (litre/min)
Flow rate (litre/min)
Flow rate (litre/min)
Drive speed (rpm)
620R performance graph
Flow rate (litre/min)
Flow rate (litre/min)
Drive speed (rpm)
620RE performance graph
NOW SELECT
YOUR DRIVE
Construction materials: 620 pumpheads are designed for ultimate impact and corrosion resistance. Pumphead track: powder-coated
aluminium LM24; guard, inner/outer: Grilamid TR55/polyurethane PBA; rotor hub, roller arms: Fortron 1140L4 (PPS); rotor cover:
Dupont Hytrel G5544; rollers, main/guide: stainless steel 303/Nylatron; main roller bearings: carbon steel; tube clamp sets: polypropylene
620 pumpheads: flow ranges, 0.1-265 rpm, litre/min
6
20R (continuous
tubing, two rollers)
620RE
(elements,
t
wo rollers)
620RE4
(elements,
f
our rollers)
Tube or
e
lement
bore
(mm, in, #)
6.4
1
/4
1
7
9.6
3
/8
1
93
12.7
1
/2
8
8
15.9
5
/4
1
89
12.0 17.0 12.0 17.0
Bioprene TM
0.004
-
9.8
0.01
-
16
0.003
-
8.3
0.004
-
11
Bioprene TL
P
ureWeld XL
0.001
-
3.4
0.003
-
6.6
0.004
-
11
0.01
-
12
0.004
-
9.8
0.01
-
18
0.003
-
8.3
0.005
-
12
Pumpsil
0
.001
-3.2
0
.003
-7.2
0
.004
-11
0
.01
-15
0
.004
-10
0
.01
-16
0
.003
-8.7
0
.004
-11
STA-PURE PCS
a
nd
S
TA-PURE PFL
0.001
-3.2
0.003
-6.6
0.004
-11
0.01
-16
0.004
-11
0.01
-18
0.003
-9.0
0.01
-13
litres/min, with pressures to 4 bar
11
Biopharm application
620U/R pumps fitted with Pumpsil platinum-cured silicone tubing are
used in a biopharm application filling single-use bags. Here they are
mounted on a trolley to allow easy transfer to the next process